Forms of Seperation

The IEC Switchboard Forms are standardized configurations defining how different electrical switchboard sections are separated. This separation improves safety by allowing maintenance or access to one part of the switchboard while other parts stay powered and functional. These forms help ensure the safe and efficient operation of the switchboard. The forms are categorized into levels: 1, 2a, 2b, 3a, 3b, 4a, and 4b, each offering varying degrees of separation and protection.

Cable Entry & Access

Cable entry and access in an electrical panel involves creating organized and protected routes for cables to enter while maintaining safety and compliance with electrical standards. These entries can beTop, bottom, or sides. An incorrect cable entry selection or unsuitable application installation can degrade the whole panel’s IP rating.

Metering & Monitoring

The need for precise power and energy monitoring grows as systems become increasingly efficient and complex. Multifunctional power meters offer real-time data that empowers energy Supervisors, technicians, engineers, and customers to optimize operations and reduce costs. The ideal meter type and capabilities will depend on the specific application’s requirements.

Busbar

Up to 6300 Amps Busbar
Busbars are conductive bars that distribute electrical power within panels or enclosures. They are used in various applications, such as electrical panels, switchboards, and industrial equipment. Vawell Power
primarily uses copper bus bars, both rigid and flexible, with a capacity of up to 6300 Amps.

Fault Rating

Vawell Power Solution LV Switchboards, Control Panels are designed with Fault rating. Fault rating is a critical factor in ensuring that electrical systems and their components can safely manage fault conditions, preventing equipment failure and ensuring overall system integrity..

Ingress Protection

System Ingress Protection
Vawell Power Low-voltage Switchboard/Distribution Boards/, Control Panels Steelwork has an ingress protection (IP) rating of up to IP54;
● Protection against dust (limited intrusion)
● Protection against splashing water

Bespoke steelwork Ingress Protection —Up to IP65/66
● Dust-tight (no dust entry).
● Protection against low-pressure water jets.

Fixed Plugin or Withdrawal Services

Vawell Power offers a range of methods and product features to support efficient maintenance and servicing. By partnering with all major suppliers, we provide a comprehensive selection of components
tailored to meet diverse requirements.

Finishes

Vawell power standard paint finish is a powdered coat, White and light grey (RAL 7035). Other colors are available on request

Surge Suppression

Surge Suppression/ Surge Protective Device diverts excess voltage away from connected devices, preventing damage to electronics, circuits, and components.

Types of Surge Suppression Devices;

  • Type 1 – Service Entrance SPDs
  • Type 2 – Panel or Branch Circuit SPDs
  • Type 3 – Point-of-Use Surge Protectors

Special Specification

We design and deliver control panels tailored to meet the unique specifications of a wide range of industries, ensuring optimal performance and seamless integration with your specific operational needs.

FORMS OF SEPERATIONS

The IEC Switchboard Forms are standardized configurations defining how different electrical switchboard sections are separated. This separation improves safety by allowing maintenance or access to one part of the switchboard while other parts stay powered and functional. These forms help ensure the safe and efficient operation of the switchboard. The forms are categorized into levels: 1, 2a, 2b, 3a, 3b, 4a, and 4b, each offering varying degrees of separation and protection.

CABLE ENTRY
& ACCESS

Cable entry and access in an electrical panel involves creating organized and protected routes for cables to enter while maintaining safety and compliance with electrical standards. These entries can beTop, bottom, or sides. An incorrect cable entry selection or unsuitable application installation can degrade the whole panel’s IP rating.

METERING &
MONITORING

The need for precise power and energy monitoring grows as systems become increasingly efficient and complex. Multifunctional power meters offer real-time data that empowers energy Supervisors, technicians, engineers, and customers to optimize operations and reduce costs. The ideal meter type and capabilities will depend on the specific application’s requirements.

BUSBAR

Up to 6300 Amps Busbar
Busbars are conductive bars that distribute electrical power within panels or enclosures. They are used in various applications, such as electrical panels, switchboards, and industrial equipment. Vawell Power
primarily uses copper bus bars, both rigid and flexible, with a capacity of up to 6300 Amps.

FAULT RATING

Vawell Power Solution LV Switchboards, Control Panels are designed with Fault rating. Fault rating is a critical factor in ensuring that electrical systems and their components can safely manage fault conditions, preventing equipment failure and ensuring overall system integrity..

INGRESS
PROTECTION

System Ingress Protection

Vawell Power Solutions Low-voltage Switchboard/Distribution Boards/, Control Panels Steelwork has an ingress protection (IP) rating of up to IP54;

● Protection against dust (limited intrusion)
● Protection against splashing water

Bespoke steelwork Ingress Protection —Up to IP65/66

● Dust-tight (no dust entry).
● Protection against low-pressure water jets.

FIXED PLUGIN
OR WITHDRAWAL DEVICES

Vawell Power offers a range of methods and product features to support efficient maintenance and servicing. By partnering with all major suppliers, we provide a comprehensive selection of components
tailored to meet diverse requirements.

FINISHES

Vawell power standard paint finish is a powdered coat, White and light grey (RAL 7035). Other colors are available on request

SURGE SUPRESSION

Surge Suppression/ Surge Protective Device diverts excess voltage away from connected devices, preventing damage to electronics, circuits, and components.

Types of Surge Suppression Devices;

  • Type 1 – Service Entrance SPDs
  • Type 2 – Panel or Branch Circuit SPDs
  • Type 3 – Point-of-Use Surge Protectors

SPECIAL SPECIFICATION

We design and deliver control panels tailored to meet the unique specifications of a wide range of industries, ensuring optimal performance and seamless integration with your specific operational needs.