Home – Products
The IEC Switchboard Forms are standardized configurations defining how different electrical switchboard sections are separated. This separation improves safety by allowing maintenance or access to one part of the switchboard while other parts stay powered and functional. These forms help ensure the safe and efficient operation of the switchboard. The forms are categorized into levels: 1, 2a, 2b, 3a, 3b, 4a, and 4b, each offering varying degrees of separation and protection.
Cable entry and access in an electrical panel involves creating organized and protected routes for cables to enter while maintaining safety and compliance with electrical standards. These entries can beTop, bottom, or sides. An incorrect cable entry selection or unsuitable application installation can degrade the whole panel’s IP rating.
The need for precise power and energy monitoring grows as systems become increasingly efficient and complex. Multifunctional power meters offer real-time data that empowers energy Supervisors, technicians, engineers, and customers to optimize operations and reduce costs. The ideal meter type and capabilities will depend on the specific application’s requirements.
Up to 6300 Amps Busbar
Busbars are conductive bars that distribute electrical power within panels or enclosures. They are used in various applications, such as electrical panels, switchboards, and industrial equipment. Vawell Power
primarily uses copper bus bars, both rigid and flexible, with a capacity of up to 6300 Amps.
Vawell Power Solution LV Switchboards, Control Panels are designed with Fault rating. Fault rating is a critical factor in ensuring that electrical systems and their components can safely manage fault conditions, preventing equipment failure and ensuring overall system integrity..
System Ingress Protection
Vawell Power Low-voltage Switchboard/Distribution Boards/, Control Panels Steelwork has an ingress protection (IP) rating of up to IP54;
● Protection against dust (limited intrusion)
● Protection against splashing water
Bespoke steelwork Ingress Protection —Up to IP65/66
● Dust-tight (no dust entry).
● Protection against low-pressure water jets.
Vawell Power offers a range of methods and product features to support efficient maintenance and servicing. By partnering with all major suppliers, we provide a comprehensive selection of components
tailored to meet diverse requirements.
Vawell power standard paint finish is a powdered coat, White and light grey (RAL 7035). Other colors are available on request
Surge Suppression/ Surge Protective Device diverts excess voltage away from connected devices, preventing damage to electronics, circuits, and components.
Types of Surge Suppression Devices;
We design and deliver control panels tailored to meet the unique specifications of a wide range of industries, ensuring optimal performance and seamless integration with your specific operational needs.
This is front side content.
The IEC Switchboard Forms are standardized configurations defining how different electrical switchboard sections are separated. This separation improves safety by allowing maintenance or access to one part of the switchboard while other parts stay powered and functional. These forms help ensure the safe and efficient operation of the switchboard. The forms are categorized into levels: 1, 2a, 2b, 3a, 3b, 4a, and 4b, each offering varying degrees of separation and protection.
FORM OF SEPERATION
CABLE ENTRY AND ACCESS
METERING AND MONITORING
BUSBAR
FAULT RATING
INGRESS PROTECTION
FIXED PLUGIN OR WITHDRAWAL DEVICES
FINISHES
SURGE SUPRESSION
SPECIAL SPECIFICATION
Vawell Power Solutions is an integrated building services solutions provider that is passionate about being innovatively forward thinking in order to meet various client aspirations through our wide range of product portfolio
+234(0) 811 111 0102
vawellpower@gmail.com, info@vawellpower.com
Lagos: 28 Alh. Kehinde Street, Abule-Egba,
Lagos, Nigeria.
Canada: Unit 4, 158 Lebrun Street,
Vanier Ontario K1L 5C9.
Copyright © 2025 All Right Reserved
The IEC Switchboard Forms are standardized configurations defining how different electrical switchboard sections are separated. This separation improves safety by allowing maintenance or access to one part of the switchboard while other parts stay powered and functional. These forms help ensure the safe and efficient operation of the switchboard. The forms are categorized into levels: 1, 2a, 2b, 3a, 3b, 4a, and 4b, each offering varying degrees of separation and protection.
Cable entry and access in an electrical panel involves creating organized and protected routes for cables to enter while maintaining safety and compliance with electrical standards. These entries can beTop, bottom, or sides. An incorrect cable entry selection or unsuitable application installation can degrade the whole panel’s IP rating.
The need for precise power and energy monitoring grows as systems become increasingly efficient and complex. Multifunctional power meters offer real-time data that empowers energy Supervisors, technicians, engineers, and customers to optimize operations and reduce costs. The ideal meter type and capabilities will depend on the specific application’s requirements.
Up to 6300 Amps Busbar
Busbars are conductive bars that distribute electrical power within panels or enclosures. They are used in various applications, such as electrical panels, switchboards, and industrial equipment. Vawell Power
primarily uses copper bus bars, both rigid and flexible, with a capacity of up to 6300 Amps.
Vawell Power Solution LV Switchboards, Control Panels are designed with Fault rating. Fault rating is a critical factor in ensuring that electrical systems and their components can safely manage fault conditions, preventing equipment failure and ensuring overall system integrity..
System Ingress Protection
Vawell Power Solutions Low-voltage Switchboard/Distribution Boards/, Control Panels Steelwork has an ingress protection (IP) rating of up to IP54;
● Protection against dust (limited intrusion)
● Protection against splashing water
Bespoke steelwork Ingress Protection —Up to IP65/66
● Dust-tight (no dust entry).
● Protection against low-pressure water jets.
Vawell Power offers a range of methods and product features to support efficient maintenance and servicing. By partnering with all major suppliers, we provide a comprehensive selection of components
tailored to meet diverse requirements.
Vawell power standard paint finish is a powdered coat, White and light grey (RAL 7035). Other colors are available on request
Surge Suppression/ Surge Protective Device diverts excess voltage away from connected devices, preventing damage to electronics, circuits, and components.
Types of Surge Suppression Devices;
We design and deliver control panels tailored to meet the unique specifications of a wide range of industries, ensuring optimal performance and seamless integration with your specific operational needs.